The conventional outflow pathway remains an important target in the surgical management of glaucoma. Although the principle of trabecular bypass appears straightforward, our understanding of the anatomy and physiology underlying this approach has evolved considerably.

In a presentation at the 2026 European Glaucoma Society (EGS) meeting, Professor Norbert Pfeiffer explained that in glaucoma, structural and functional changes within the trabecular meshwork increase resistance to aqueous outflow. This provided the rationale for early trabecular bypass procedures. By creating direct access from the anterior chamber to Schlemm’s canal, these procedures bypass a major source of resistance within the conventional outflow pathway.

Early clinical experience, however, demonstrated that the relationship between trabecular bypass and IOP reduction is not entirely straightforward. In a randomized study by Samuelson and colleagues, implantation of an iStent combined with cataract surgery resulted in a substantial reduction in IOP.1 However, a similar reduction was observed with cataract surgery alone, although patients receiving the stent required fewer glaucoma medications.1

These observations raised an important question. If much of the resistance to aqueous outflow resides within the trabecular meshwork, why does creating a small opening into Schlemm’s canal not necessarily produce a greater additional reduction in IOP?

Schlemm’s canal is not a uniform conduit

Part of the answer lies in the anatomy of Schlemm’s canal and the distal outflow system. The canal is not simply a uniform circumferential channel. It contains septae and valve-like structures, and collector channels are not distributed evenly around its circumference. Consequently, aqueous entering Schlemm’s canal at one location may have direct access to functioning collector channels, whereas flow from another location may be considerably more limited.

Professor Norbert Pfeiffer explained that this anatomical variability has implications for how Schlemm’s canal is accessed therapeutically. Because the location of an opening can influence the amount of outflow achieved, approaches may involve creating multiple openings or using a larger stent to provide access across a greater portion of the canal.

The rationale for Hydrus Microstent

The Hydrus® Microstent was designed around this broader understanding of conventional outflow. The 8-mm device spans around 90 degrees of Schlemm’s canal and combines trabecular bypass with scaffolding of the canal. Its open architecture is intended to maintain access to the outer wall and collector channel ostia across the treated segment.

Experimental work by Gong provides further support for this mechanism. Using fluorescein tracer models, they demonstrated increased aqueous outflow following Hydrus implantation, with a broader distribution of tracer around the segment of Schlemm’s canal spanned by the device.3 Experimental comparisons also showed substantially greater enhancement of outflow with Hydrus than with a single focal trabecular opening.3

Histologic observations provide further insight into how the device interacts with Schlemm’s canal.4 Following removal of the implant, microscopic examination has demonstrated preservation of the outer wall of the canal and surrounding structures, supporting the ability of the device to scaffold Schlemm’s canal while maintaining access to the downstream outflow pathway.4

Translating the mechanism into clinical outcomes

The mechanistic rationale has subsequently been evaluated in randomized clinical trials comparing Hydrus implantation combined with cataract surgery against cataract surgery alone.5,6

At 12 and 24 months, 85.9% and 77.3% of patients receiving Hydrus with cataract surgery, respectively, achieved a ≥20% reduction in medication-washout IOP from baseline, compared with 70.0% and 57.8% of patients undergoing cataract surgery alone (Hydrus, n=369; cataract surgery alone, n=187; P<0.001 at both time points).6 The longer-term findings also showed that some patients remained free from glaucoma medications five years after treatment.7

Cataract surgery is effective on IOP, but much less so than the combined procedure. The evidence for Hydrus shows not only a pressure-lowering effect, but an effect that is maintained over a longer period of time.8 For patients, reducing dependence on topical therapy may have implications beyond IOP alone, particularly in relation to treatment burden, adherence and the cumulative impact of chronic topical medication.9

Beyond pressure lowering

Ultimately, however, the purpose of glaucoma treatment is not simply to lower IOP or reduce the number of medications. It is to preserve visual function.

Long-term analyses of the HORIZON population have therefore examined whether the clinical benefits observed following Hydrus implantation are accompanied by differences in visual field progression. In a post hoc analysis, Montesano and colleagues evaluated visual field progression among patients with at least 3 reliable postoperative visual field assessments. The mean rate of visual field progression was approximately −0.26 dB/year in eyes receiving Hydrus with cataract surgery (n=352) compared with −0.49 dB/year following cataract surgery alone (n=165; P=0.0138).10 This detailed visual field progression analysis was not prespecified in the HORIZON trial and the findings should therefore be interpreted in the context of a post hoc analysis

The evolution of MIGS has changed how we think about the conventional outflow pathway. The trabecular meshwork remains an important source of resistance, but gaining access to Schlemm’s canal is only part of the equation. The anatomy of the canal, the distribution of collector channels and the extent of the outflow pathway accessed by an intervention may all influence its effectiveness.

Hydrus was designed around this broader concept. By combining trabecular bypass with scaffolding of approximately 90 degrees of Schlemm’s canal, the device provides access to a larger portion of the conventional outflow pathway rather than relying on a single focal opening.6,11 Randomized clinical trials and long-term follow-up have subsequently demonstrated sustained reductions in IOP and medication burden compared with cataract surgery alone.6,7 Longer-term analyses also provide evidence of slower visual field progression.10

Together, these findings support a broader way of thinking about trabecular bypass. The question is not simply whether the trabecular meshwork can be bypassed, but how effectively that intervention provides access to the functional outflow system beyond it.

©2026 Alcon Inc. 10/26 IMG-HDM-2600067

References

  1. Samuelson TW, Jay Katz L, Wells JM, et al. Randomized evaluation of the trabecular micro-bypass stent with phacoemulsification in patients with glaucoma and cataract. Ophthalmology. 2011;118(3):459-67.
  2. Figure source: Grehn F, Mackensen G, Die Glaukome. 1993
  3. Gong H, Cha ED, Gorantla V, et al. Characterization of Aqueous Humor Outflow through Novel Glaucoma Devices - A Tracer Study. ARVO Annual Meeting Abstract 2012.
  4. Grierson I, Saheb H, Kahook MY, Johnstone MA, Ahmed II, Schieber AT, et al. A novel Schlemm's canal scaffold: histologic observations. J Glaucoma. 2015;24(6):460–468.
  5. Pfeiffer N, Garcia-Feijoo J, Martinez-de-la-Casa JM, et al. A Randomized Trial of a Schlemm's Canal Microstent with Phacoemulsification for Reducing Intraocular Pressure in Open-Angle Glaucoma. Ophthalmology. 2015;122(7):1283-93.
  6. Samuelson TW, Chang DF, Marquis R, et al. A Schlemm Canal Microstent for Intraocular Pressure Reduction in Primary Open-Angle Glaucoma and Cataract: The HORIZON Study. Ophthalmology. 2019;126(1):29-37.
  7. Ahmed IIK, De Francesco T, Rhee D, et al. Long-term Outcomes from the HORIZON Randomized Trial for a Schlemm's Canal Microstent in Combination Cataract and Glaucoma Surgery. 2022;129(7):742-751.
  8. Alcon Data on File, 2024. REF-24145.
  9. Patel AR, Schwartz GF, Campbell JH, et al. Economic and clinical burden associated with intensification of glaucoma topical therapy: A US claims-based analysis. Journal of Glaucoma. 2020;30(3):242-250. doi:10.1097/ijg.0000000000001730
  10. Montesano G, Ometto G, Ahmed IIK, Ramuulu PY, Chang DF, Crabb DP, Gazzard G. Five-year visual field outcomes of the horizon trial. Am. J. Ophthalmol. 2023;251:143-155. https://doi.org/10.1016/j.ajo.2023.02.008.
  11. Hydrus Microstent Instructions for Use – US. REF-16346

Related to this article