Optegra Poland is a network of 13 specialized clinics providing ophthalmology and vision correction services in nine major cities across Poland. With a commitment to optimize patient outcomes, the evaluation of new technologies that can expand our range of available treatment options is an ongoing process.

I joined Optegra Poland as a refractive surgeon in 2016, and I became the refractive team manager in 2018. As I had seen a growing number of relatively younger patients with presbyopia and no evidence of cataract presenting with a desire to reduce their dependence on reading glasses, I recognized there was a need for a cornea-based solution that would provide a less invasive alternative to refractive lens exchange for these individuals and others who are not ideal candidates for lens-based surgery.

I was interested in ZEISS PRESBYOND because of the encouraging results reported in the literature for this option. Reviewing the treatment concepts and clinical outcomes described by Professor Dan Z. Reinstein provided compelling information that convinced our group that implementing PRESBYOND® would bring value to our clinics.

ZEISS PRESBYOND is realized by means of a binocular LASIK procedure performed with the MEL 90 excimer laser (Carl Zeiss Meditec AG; Jena, Germany) that uses a customized ablation profile mapped out by dedicated proprietary planning software. Able to correct refractive error as well, it addresses presbyopia by increasing depth of field using the principle of micro-anisometropia and induction of a controlled amount of spherical aberration in each eye. The ablation targets the dominant eye for plano and the nondominant eye for a defined near target, creating a continuous aspheric corneal profile that aims to preserve visual quality and contrast sensitivity, parameters that have been reported as potential limitations of multifocal optical approaches.1-6

Initial experience

I performed my first laser vision correction planned with ZEISS PRESBYOND in 2018 and have followed that patient for seven years. The patient was a 56-year-old male with low hyperopia and low astigmatism (+1.5/-0.75@80 OD, +1.25/-0.5@95 OS). His binocular decimal best corrected visual acuity (BCVA) was 1.25 (Snellen 20/16) and binocular corrected near visual acuity (CNVA) was 0.5 (Snellen 20/40).

The surgery was successful. The patient was highly satisfied with the outcome from the very first postoperative day and achieved complete spectacle independence at all distances. The patient returned 1 year after surgery. At that time, his dominant eye was slightly overcorrected, but he remained spectacle-free at distance and near with binocular uncorrected VA values of 1.1 and 0.5, respectively.

I saw the patient again at 2 years postoperatively. At that visit his dominant eye refraction was plano and his binocular VA was 1.25 for distance and 0.5 for near. In 2025, 7 years after laser vision correction with ZEISS PRESBYOND, there was very slight refractive regression in both eyes. However, at age 63, this gentleman remained free from needing glasses for far and near with binocular VA results of 1.0 and 0.5, respectively.

Documenting success

The positive early results achieved in this initial case made me comfortable to continue offering ZEISS PRESBYOND to appropriately selected patients. Outcomes in an unpublished retrospective analysis of 50 consecutive patients followed for 1 year after surgery at Optegra Poland provide confidence that the results achieved in my first case reflect the norm and are not a rare exception.

For this study we identified myopic patients with or without astigmatism who were age 40 to 55 years with monocular BCVA ≥0.9, tolerance of micromonovision from -0.75 to -1.75 D sphere, and data from return visits at 1 day, and 1, 3, and 12 months after surgery. The patients were predominantly male (78%) and had a mean age of 45 years with a mean preoperative spherical equivalent (SEQ) of -4.41 D. The target for micro-anisometropia was between -1.0 D and -1.5 D in 94% of cases but ranged from -0.75 D to -1.75 D.

Looking at binocular distance UCVA at 12 months postoperatively, 98% (n = 49) of patients achieved 20/20 or better, 64% (n = 32) achieved 20/16 or better, and 6% (n = 3) achieved even 20/12.5. For binocular near UCVA, 98% of patients achieved 20/40 or better.

Using data from the dominant eyes, our analysis of predictability showed excellent results consistent with those achieved when performing LASIK for myopic astigmatism.7 Postoperative SEQ was ±0.5 D of target in 94% of eyes and ± 0.13 of target in 58% of eyes. Furthermore, the refractive results showed good stability between 3 months and 1 year with mean SE values at those visits being -0.06 ± 0.24 and -0.14 ± 0.25 D, respectively. Safety was confirmed with no cases of BCVA loss ≥2 lines and no intraoperative or postoperative complications.

Results of a satisfaction questionnaire that was completed by 30 of the 50 patients showed that the majority of responders reported that their vision quality was “better” or “much better” postoperatively compared with preoperative glasses or contact lenses, and 100% were satisfied with their unaided postoperative vision and would consider undergoing the procedure again based on the final outcome. Twenty-nine respondents (97%) would recommend the procedure to family and friends, and 100% of the respondents reported surgery delivered what individuals seek when choosing this procedure – freedom from glasses or contact lenses. Although satisfaction levels of the 40% of patients who did not complete the questionnaire remain unknown, it seems reasonable to expect that if unhappy, the patients would have used the opportunity to provide negative feedback.

Ideas on implementation

Since introducing ZEISS PRESBYOND in 2018, I have personally performed more than 2,700 laser vision corrections with PRESBYOND®. This extensive surgical experience has contributed significantly to our understanding of patient selection, visual adaptation, and the optimization of treatment outcomes.

Standardization and proper patient selection are of paramount importance for achieving success when implementing any new refractive procedure into our clinics. Therefore, uniform diagnostic and treatment criteria are applied to ensure predictable outcomes and allow a reliable evaluation of treatment efficacy. In addition, good tolerance of the induced micromonovision is key for identifying patients who are likely to be satisfied after laser vision correction with ZEISS PRESBYOND. Therefore, assessment of cross-blur tolerance is a critical component of the preoperative examination, and the assessment is performed both at the qualification visit and before surgery. Measurement of ocular spherical aberration is essential during patient selection and preoperative assessment for ZEISS PRESBYOND treatment.

Ideally patients should be able to tolerate -0.75 to -1.50 D of micromonovision. Those who tolerate only -0.25 D to -0.50 D of micromonovision are not absolutely excluded. However, because they tend to have greater sensitivity to any residual refractive error, I have a different conversation with them during the qualification visit to establish appropriate expectations regarding visual acuity outcomes, possible need for glasses in the future, and potential enhancements given that presbyopia is a progressive condition.

Based on my extensive experience, I believe that the best initial candidates for ZEISS PRESBYOND laser vision correction are patients with low to moderate myopia (< −5.00 D sphere) and low to moderate astigmatism (< 1.50 D cylinder), or patients with low hyperopia (< +2.00 D sphere) and low to moderate astigmatism (< 1.50 D cylinder). Because laser vision correction with ZEISS PRESBYOND is a LASIK procedure, patients must also meet all the usual criteria for LASIK eligibility, which is determined by conducting a comprehensive ophthalmic examination and evaluating the patient’s visual needs, lifestyle, and expectations. I have discovered that age should not be a fixed criterion for offering laser vision correction with ZEISS PRESBYOND. In our clinic we offer it to anyone who remains a suitable candidate (e.g., age 54 is not treated as a strict cutoff).

Conclusion

Laser vision correction with ZEISS PRESBYOND closes a gap in the surgical management of presbyopia by providing a safe and effective corneal based solution for patients in the absence of cataract. The results of the study reported here are consistent with my large overall experience and with those reported in the world’s literature in showing that laser vision correction with ZEISS PRESBYOND delivers great early and long-term refractive and functional outcomes along with a high level of patient satisfaction. I think colleagues will agree that happy patients make happy surgeons, and through eagerness to share their experience, they are also a great asset for helping grow a refractive surgery practice.

Katarzyna Skonieczna, MD, PhD

Adrianna Wyrębiak, MOptom



References:

1. Russo A, Reinstein DZ, Filini O, t al. Visual and refractive outcomes following laser blended vision with non-linear aspheric micro-anisometropia (PRESBYOND) in myopic and hyperopic patients. J Refract Surg. 2022;38(5):288-297.

2. Ganesh S, Brar S, Gautam M, Sriprakash K. Visual and refractive outcomes following laser blended vision using non-linear aspheric micro-monovision. J Refract Surg. 2020;36(5):300-307.

3. Wierzbowska J, Pniakowska Z, Roszkowska AM. Contrast sensitivity and stereopsis outcomes following LASIK presbyopia correction based on the corneal aberration Modulation or corneal multifocality induction methods: a systematic review. J Clin Med. 2025;14(3):871.

4. American Academy of Ophthalmology. Multifocal and EDOF IOLs offer good visual acuity, reduced contrast sensitivity [Internet]. San Francisco (CA): American Academy of Ophthalmology. Available from: https://www.aao.org/education/editors-choice/multifocal-edof-iols-offer-good-visual-acuity-redu. Accessed October 1, 2026.

5. Salerno LC, Tiveron MC Jr, Alió JL. Multifocal intraocular lenses: Types, outcomes, complications and how to solve them. Taiwan J Ophthalmol. 2017;7(4):179-184.

6. Kim CY, Chung SH, Kim TI, et al. Comparison of higher-order aberration and contrast sensitivity in monofocal and multifocal intraocular lenses. Yonsei Med J. 2007;31;48(4):627-33.

7. Reinstein DZ, Carp GI, Lewis TA, Archer TJ, Gobbe M. Outcomes for Myopic LASIK With the MEL 90 Excimer Laser. J Refract Surg. 2015;31(5):316-321.

en-OUS_34_021_0090I The statements of the authors reflect only their personal opinions and experiences and do not necessarily reflect the opinion of any institution that they are affiliated with. The authors alone are responsible for the content of their experience reported and any potential resulting infringements. Carl Zeiss Meditec AG and its affiliates do not have clinical evidence supporting the opinions and statements of the authors nor accept any responsibility or liability of the authors’ content. MEL 90 and PRESBYOND are either trademarks or registered trademarks of Carl Zeiss Meditec AG or other companies of the ZEISS Group in Germany and / or other countries. Products referenced may not be available in all countries and product labeling varies by country.