Article

Visual acuity a multifactorial metric

Although image quality has a clear influence on visual acuity, it does not account for all the individual variability of other factors that must be involved including, measurement errors, or wavefront, optical or neural factors, Raymond Applegate said.

Although image quality has a clear influence on visual acuity, it does not account for all the individual variability of other factors that must be involved including, measurement errors, or wavefront, optical or neural factors, Raymond Applegate said.

Wavefront factors could include visual performance, while optical factors include issues like scatter or chromatic aberration. Neural factors include cone sampling, internal noise and cognitive issues, he remarked.

"In eyes with normal to excellent photopic high contrast (P HC) acuity, optical quality metrics increase in predictive value with increasing difficulty of the visual task," he said.

The more difficult the task, the more detailed and refined the ultimate visual acuity measurement will be. In the case of normal healthy eyes, high photopic stimuli makes P HC acuity insensitive to minor variations in wavefront error. As such, it's a less accurate metric.

For example, higher order aberrations (HOA) account for only 4% of the variance in photopic high contrast acuity. That means, only 4% of HOAs are detected. "In comparison, mesopic low contrast (M LC) acuity is eight times more sensitive than photopic high contrast acuity to the same variation in optical quality accounting for 37% of the variance in acuity."

Mesopic low contrast stimuli contain less redundant information and are therefore more sensitive to minor variations in image quality.

In a clinical environment the effect of minor variations on optical quality can be assessed with mesopic low contrast acuity, but not with photopic high contrast acuity, Dr Applegate noted.

Ophthalmology Times Europe reporting from the XXIV Congress of the ESCRS, London, 9-13 September, 2006.

Newsletter

Don’t miss out—get Ophthalmology Times updates on the latest clinical advancements and expert interviews, straight to your inbox.

Related Videos
(Image credit: Ophthalmology Times) NeuroOp Guru: Using OCT to forecast outcomes in ethambutol optic neuropathy
(Image credit: Ophthalmology Times) Inside NYEE’s new refractive solutions center with Kira Manusis, MD
(Image credit: Ophthalmology Times) Dilsher Dhoot, MD, on the evolution of geographic atrophy therapy: where are we now?
(Image credit: Ophthalmology Times Europe) Anat Loewenstein, MD, shares insights on the real-world results of remote retinal imaging
(Image credit: Ophthalmology Times) Two-wavelength autofluorescence for macular xanthophyll carotenoids with Christine Curcio, PhD
(Image credit: Ophthalmology Times) FLIO and the brain: Making the invisible visible with Robert Sergott, MD
(Image credit: Ophthalmology Times) Structure-function correlates using high-res OCT images with Karl Csaky, MD, PhD
(Image credit: Ophthalmology Times) SriniVas Sadda, MD, on high-res OCT of atrophic and precursor lesions in AMD
(Image credit: Ophthalmology Times) Christine Curcio, PhD, shares histology update supporting review software and revised nomenclature for <3 μm OCT
© 2025 MJH Life Sciences

All rights reserved.